camp glosensor (20f) biosensor hek293g (Promega)
Structured Review

Camp Glosensor (20f) Biosensor Hek293g, supplied by Promega, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/camp glosensor (20f) biosensor hek293g/product/Promega
Average 90 stars, based on 1 article reviews
Images
1) Product Images from "A novel and selective fluorescent ligand for the study of adenosine A 2B receptors"
Article Title: A novel and selective fluorescent ligand for the study of adenosine A 2B receptors
Journal: Pharmacology Research & Perspectives
doi: 10.1002/prp2.1223
Figure Legend Snippet: Effect of PSB603‐BY630 on Glosensor cAMP concentration‐response curves to the A 2B ‐selective agonist BAY 60–6583 in (A) HEK293G cells endogenously expressing A 2B R or (B) HEK293G cells overexpressing NLuc‐A 2B R. Concentration response curves were obtained in the absence and presence of 20 nM or 200 nM PSB603‐BY630. Values are mean ± S.E.M. of five separate experiments carried out in triplicate. Data represent peak luminescence response and are expressed as a percentage of the peak luminescence response to 3 μM BAY 60–6583 (in a) or 0.3 μM BAY 60–6583 (in b) obtained in the absence of antagonist in each individual experiment.
Techniques Used: Concentration Assay, Expressing